top of page

INTRODUCTION

Fire Safety Alarm Monitoring

It’s a system where your fire alarms (from smoke, heat, flame, sprinkler flow, etc.) are connected to a central monitoring station, typically staffed 24/7. When an alarm triggers, the system automatically sends a signal—over the internet, cellular, radio, or phone line—to this station

⚙️ 2. How It Works (Step-by-Step)

  1. Detection: Sensors located in zones (conventional) or with unique IDs (addressable) detect smoke, heat, flame, or sprinkler activation.

  2. Signal Transmission: The fire alarm control panel uses a communicator (e.g., DACT, cellular, IP) to relay the event to the monitoring center 

  3. Monitoring Center Response: Operators verify the alert, contact the building owner/emergency contacts, and dispatch local fire services if needed

  4. Action: Firefighters are notified even if you're asleep or away—response can begin within seconds, not minutes.

Fire Equipment 

📌 1. Fire Alarm Control Panel (FACP)

  • Acts as the central brain, continuously monitoring inputs and system integrity.

  • Receives signals from detectors and manual pull stations, distinguishes real events from false alarms, and initiates notification devices.

  • Advanced panels log events, self-test, integrate with HVAC or access systems, and allow remote/cloud monitoring 

🔥 2. Initiating Devices (Fire Detectors / Pull Stations)

🔹 Smoke Detectors

  • Available as ionization (fast flame), photoelectric (slow smolder), or dual sensors.

  • There are also beam-type and aspirating (air-sampling) detectors ideal for large or high-risk areas 

🔹 Heat Detectors

  • Triggered by reaching a set temperature (fixed) or detecting rapid temperature rise.

🔹 Flame Detectors

  • Detect flame-specific light signatures; useful for special-risk environments like industrial sites.

🔹 Manual Pull Stations (Call Points)

  • Human-operated emergency alarms activated by pulling or pushing in hallways, exits, etc. 

🔹 Duct Detectors & Waterflow Switches

  • Inspect HVAC duct smoke and sprinkler water flow to identify hidden fires.

Pressure Monitoring

  • Pressure switches/transmitters are treated as initiating devices in sprinkler and suppression systems just like smoke detectors or manual pulls pressure.

  • These devices detect changes in water or air pressure—signaling when sprinklers activate, pipe pressure drops/rises, or air pressure deviates in dry/wet systems.

🚨 2. Types of Pressure Devices

  1. Alarm Pressure Switches

    • Trigger an alarm when water or air pressure crosses a threshold (e.g., sprinklers discharge or pipe leaks) Supervisory Pressure Switches

    • Monitor non-alarm deviations such as low air in dry-pipe systems or shut valves—these produce supervisory signals but don’t evacuate the building 

  2. Pressure Transmitters/Gauges

    • Provide analog or digital continuous pressure readings; essential for IoT/cloud dashboards, trending, and analytics 

⚙️ 3. How It Works in a System

  • When a sprinkler opens, pressure in pipes drops, triggering a switch or transmitter.

  • The fire alarm panel receives the input and either:

    • Initiates alarm activation and notification (horns, strobes), or

    • Logs a supervisory alert if it indicates a system fault or closed valve 

  • Pressure transmitters continuously send data to dashboards, helping monitor pump health, early leakage, or pipe integrity 

Pump Health 

Pump health refers to real-time tracking of a fire pump’s key performance metrics, including its mechanical, hydraulic, and electrical condition. This involves monitoring parameters like pressure, flow rate, power usage, battery charge, and even vibration or temperature—providing a holistic view of the pump’s readiness and reliability..

⚙️ Why Monitoring Pump Health Matters

  • Early Fault Detection
    Declines in pressure, abnormal vibration, or overheating can signal issues like pump wear, damage, or blockages—allowing preemptive repair before failure. 

  • Optimized Maintenance
    Predictive insights streamline service schedules, reduce unnecessary maintenance, and maximize pump lifespan.

  • Regulatory Assurance & Compliance
    Continuous logs support NFPA 20/25 and local standards by documenting pump status, test results, and fault events.

✅ 5. Key Benefits

  • Immediate Response: Alerts go out instantly, 24/7—even if you're away.

  • Enhanced Safety: Minimized delays offer better protection of life and property.

  • Trouble Notifications: Monitored systems send low‑battery, fault, tamper, and power‑loss alerts 

  • Regulatory Compliance: Meets standards such as NFPA 72, BS 5839, UL 827, and IBC—critical for commercial/industrial use 

  • Insurance & Cost Savings: Can reduce insurance premiums and legal risk while boosting peace of mind.

bottom of page